A 62 year old tech at a training in Fort Worth said my diagnostics were backwards and I'm still mad he was right | Appliance Repairers - Opinions Matter
A 62 year old tech at a training in Fort Worth said my diagnostics were backwards and I'm still mad he was right
I went to a factory training session down in Fort Worth about 6 months ago and one of the instructors, a guy who has been on the bench since the 80s, watched me work through a dryer fault and said right to my face that I was testing parts instead of testing the circuit. I got defensive at the time (I've been doing this 11 years, who is he to say that) but he pulled up his own notes and showed me how he reads a wiring diagram backwards from the load, and it cut my diagnostic time by more than half on the next 3 dryers I worked. What changed is I quit guessing at the control board and started checking continuity and voltage at each point before I ever pull a part, which saved me from swapping a $140 board that was fine last month on a Whirlpool I almost misdiagnosed. My callbacks dropped off a cliff after that, and I had to eat some crow about it. Now I write the circuit path on the back of my clipboard before I touch a meter. Curious if any of you all start from the load side or do you chase it from the supply like I used to?