Heads up: the vent on these dryers is why you keep eating the same callback twice
I picked up a dryer job in Flint last Tuesday, and the guy who had it before me replaced the thermal fuse twice in 8 months and never once pulled the vent run. Turns out the flex duct behind the unit had a crushed 90 where it met the wall, so the fuse kept popping just doing its job. Here is the part that bugs me: the error code he wrote on the ticket said "fuse bad, replaced" and nobody ever tested airflow with a meter, which takes 2 minutes. If you get a dryer that eats fuses, check static pressure and the full duct run to the outside flap first, or you will be back in that laundry room in another 8 weeks. What are you all using to check duct back pressure on tight installs?